Merlin Fork Custom Options

----------------------------------------------------------------------------------------------------------------
Stop copy of syslog files to JFFS

	Can be set in gui:	Yes (as of Update-11, Administration/System/Save syslog to JFFS)
	Enable via NVRAM:	nvram set jffs2_log=1
				nvram commit && reboot

	Routers Supported:	AC66,AC56,AC68
	Released:		Update-02
	Reboot Required:	Yes
	Notes:			Existing logs must be manually deleted from /jffs (syslog.log and syslog.log-1)
----------------------------------------------------------------------------------------------------------------
Enable Comcast DSCP fix

	Can be set in gui:	Yes (Firewall/General/Enable DSCP override)
	Enable via NVRAM:	nvram set DSCP_fix_enable=1
				nvram commit && reboot

	Routers Supported:	All
	Released:		Update-07
	Reboot Required:	Yes
	Notes:			For SOME Comcast service areas it has been seen that the
				Differentiated Services Code Point (DSCP) value is incorrectly set to a low
				priority, resulting in decreased internet throughput for wireless IPv4 transfers.
				This fix overrides that incorrect value.
----------------------------------------------------------------------------------------------------------------
Display Traffic Monitor graphs in
Mb/s (default is KB/s)

	Can be set in gui:	Yes (Tools/Other Settings/Traffic Monitor graph units)	
	Enable via NVRAM:	nvram set rstats_units=1
				nvram commit

	Routers Supported:	All
	Released:		Update-07
	Reboot Required:	No
	Notes:			Refresh or open the TM page in the browser
----------------------------------------------------------------------------------------------------------------
Multiple listening addresses and
ports for SSH access

	Can be set in gui:	No
	Enable via NVRAM:	nvram set sshd_addr=[address:]port,[address:]port,[address:]port,[address:]port
				nvram commit && reboot

	Routers Supported:	All
	Released:		Update-07
	Reboot Required:	Yes
	Notes:			Up to 4 address:port or port values may be specified separated by commas
				This will override the port setting specified in the gui
				This modifies a previous commit in Update-05 (was a single address only and now
					need to specify a port when specifying an address)
----------------------------------------------------------------------------------------------------------------
Enable full syslog records for
remote monitoring

	Can be set in gui:	Yes (Update-15)
	Enable via NVRAM:	nvram set log_small=0
				nvram commit && reboot

	Routers Supported:	All
	Released:		Update-08 (NVRAM) Update-15 (GUI)
	Reboot Required:	Yes
	Notes:			This will include the full header (including hostname and priority level) in the 
					syslogd output to enable remote monitoring
----------------------------------------------------------------------------------------------------------------
Save HTTPS certificate

	Can be set in gui:	Yes (Administration/System/Save HTTPS certificate)
	Enable via NVRAM:	nvram set https_crt_save=1
				nvram commit && reboot

	Routers Supported:	All
	Released:		Update-11
	Reboot Required:	Yes
	Notes:			If you are using HTTPS validation, the security certificate is regenerated at every
					boot, requiring you to install a new certificate in your browser.  This 
					option saves the certificate across reboots negating the need to reinstall 
					in your browser. 
----------------------------------------------------------------------------------------------------------------
Filter IPv6 Neighbor Solicitation
	
	Can be set in gui:	Yes (Firewall/General/Filter IPv6 Neighbor Solicitation)
	Enable via NVRAM:	ipv6_neighsol_drop=1 (1=Yes, 0=No)
				nvram commit
				service restart_firewall

	Routers Supported:	All
	Released:		Update-11
	Reboot Required:	No
	Notes:			Control iptables rule dropping IPv6 neighbor solicitation requests 
----------------------------------------------------------------------------------------------------------------
CROND logging options

	Can be set in gui:	No
	Enable via NVRAM:	nvram set cron_loglevel=N (default is 8)
				nvram commit && reboot

	Routers Supported:	All
	Released:		Update-11
	Reboot Required:	Yes
	Notes:			Setting cron_loglevel=N sets the logging level to N
----------------------------------------------------------------------------------------------------------------
Scan media files at every boot
	
	Can be set in gui:	Yes (USB Applications/Servers Center/Media Server/Scan media files at every boot)
	Enable via NVRAM:	nvram set dms_scan=1
				nvram commit

	Routers Supported:	All
	Released:		Update-12
	Reboot Required:	No
	Notes:			Setting to No will only scan media files when a change is detected
----------------------------------------------------------------------------------------------------------------
Enable IPv6 MTU Advertisement
	
	Can be set in gui:	Yes (IPv6/Enable IPv6 MTU Advertisement)
	Enable via NVRAM:	nvram set ipv6_radvd_mtu=1 (0 to disable)
				nvram commit

	Routers Supported:	All
	Released:		Update-13
	Reboot Required:	No
	Notes:			Default is to enable advertisement for IPv6 on all connection types
----------------------------------------------------------------------------------------------------------------
Advertise Router as IPv6 DNS Server
	
	Can be set in gui:	Yes (IPv6/Advertise router as DNS server)
	Enable via NVRAM:	nvram set ipv6_dns_router=1
				nvram commit

	Routers Supported:	All
	Released:		Update-14
	Reboot Required:	Yes
	Notes:			Enable IPv6 DNS lookups to be cached by dnsmasq
----------------------------------------------------------------------------------------------------------------
Stealth Mode - Show power status only
	
	Can be set in gui:	Yes (Tools/Other Settings/Stealth Mode/Show power status only)
	Enable via NVRAM:	nvram set led_disable=2
				nvram commit
				service restart_leds

	Routers Supported:	All
	Released:		Update-14
	Reboot Required:	No
	Notes:			Show only the power status led
----------------------------------------------------------------------------------------------------------------
HTTP Lan Port
	
	Can be set in gui:	Yes (Administration/System/HTTP Lan Port)
	Enable via NVRAM:	No, nvram variable http_lanport must be set thru gui

	Routers Supported:	All
	Released:		Update-14
	Reboot Required:	Yes
	Notes:			Changes HTTP port for gui access from default port 80
				Reset to default of 80 before loading firmware which does not support 
					changing of the port
----------------------------------------------------------------------------------------------------------------
QOS SFQ limit
	
	Can be set in gui:	No
	Enable via NVRAM:	nvram set qos_sfql=[0,off-default  1,auto  2-127,value]
				nvram commit

	Routers Supported:	All
	Released:		Update-14
	Reboot Required:	Yes
	Notes:			Changes SFQ qdisc packet limit
				A value of 1 automatically selects a value based on upload speed (recommended)
				A value of 2-127 sets this value as the packet limit
----------------------------------------------------------------------------------------------------------------
SNTP Server
	
	Can be set in gui:	Yes (Administration/System/Enable router as local SNTP server)
	Enable via NVRAM:	nvram set ntpd_server=1
				nvram commit
				service restart_time

	Routers Supported:	All
	Released:		Update-15
	Reboot Required:	No
	Notes:			Enables the router to act as an SNTP time server
				User 'router.asus.com' as your SNTP server
----------------------------------------------------------------------------------------------------------------
Networkmap UNIX/Linux Clients as PC
	
	Can be set in gui:	No setting required
	Enable via NVRAM:	No setting required

	Routers Supported:	All
	Released:		Update-15
	Reboot Required:	No
	Notes:			You must install SAMBA and winbind on the client for the client to be 
					recognized as a PC
----------------------------------------------------------------------------------------------------------------
Disable Avahi (mDNS) Reflector
	
	Can be set in gui:	No
	Enable via NVRAM:	nvram set mdns_reflector=0
				nvram commit
				service restart_mdns

	Routers Supported:	All
	Released:		Update-15
	Reboot Required:	No
	Notes:			Changes the default state of the Avahi reflector to disabled
----------------------------------------------------------------------------------------------------------------
Enable logging of successful NTP updates
	
	Can be set in gui:	No
	Enable via NVRAM:	nvram set ntp_log=0
				nvram commit

	Routers Supported:	All
	Released:		Update-15
	Reboot Required:	No
	Notes:			Successful NTP updates are not logged by default, fails are always logged
				This option enables logging of successful updates
----------------------------------------------------------------------------------------------------------------
Set NTP update interval
	
	Can be set in gui:	Yes (Administration/System/Router NTP update interval (hours))
	Enable via NVRAM:	nvram set ntp_update=[interval in hours]
				nvram commit

	Routers Supported:	All
	Released:		Update-15 w/o gui support, Update-16 w/ gui support
	Reboot Required:	No
	Notes:			Default is that the router will update with its NTP server every hour
				This option changes the number of hours between updates.  The value is not currently error
					checked and should be an integer between 1 and 24 (hours)
				A value of '0' disables NTP updates and the time must be set manually (Update-16)
----------------------------------------------------------------------------------------------------------------
Set NTP alternate time server

	Can be set in gui:	Yes (Administration/System/NTP Server (Alternate))
	Enable via NVRAM:	nvram set ntp_update=[interval in hours]
				nvram commit

	Routers Supported:	All
	Released:		Update-15 w/o gui support, Update-16 w/ gui support
	Reboot Required:	No
	Notes:			Default is that the router will update with its NTP server every hour
				This option changes the number of hours between updates.  The value is not currently error
					checked and should be an integer between 1 and 24 (hours)
				A value of '0' disables NTP updates and the time must be set manually (Update-16)

----------------------------------------------------------------------------------------------------------------
Special support for Private Internet Access (PIA) OpenVPN Client

	Can be set in gui:	Yes (Administration/System/NTP Server (Alternate))
	Enable via NVRAM:	N/A (see pia_openvpn_options.zip in the download directory)

	Routers Supported:	All
	Released:		Update-16
	Reboot Required:	No
	Notes:			You can now set cipher, authentication and encryption options via the router as you would
					using the PIA app.
				You need to add a line to the custom config section and replace the ca with a new cert
					(included in the zip) in addition to setting the appropriate OpenVPN options.
----------------------------------------------------------------------------------------------------------------
Set number of threads for NVS server

	Can be set in gui:	No
	Enable via NVRAM:	nvram set nfsd_threads=x (where x is the number of threads)
				nvram commit & service restart_nfs

	Routers Supported:	All
	Released:		Update-17
	Reboot Required:	No
	Notes:			The default number of threads has now been raised to two (instead of a single thread)
---------------------------------------------------------------------------------------------------------------
Set preferred interface for bandwidth limiter

	Can be set in gui:	No
	Enable via NVRAM:	nvram set qos_iface=[iface]
				nvram commit && reboot

	Routers Supported:	All
	Released:		Update-17
	Reboot Required:	No
	Notes:			The default interface is eth0 (standard WAN interface).   This may be useful if running
					an OpenVPN client and wish to limit that bandwidth (set to tun11 for example for
					vpnclient1.
---------------------------------------------------------------------------------------------------------------
Use alternate NAT Loopback implementation (ASUS)

	Can be set in gui:	No
	Enable via NVRAM:	nvram set fw_nat_loopback=1
				nvram commit && reboot

	Routers Supported:	All
	Released:		Update-17
	Reboot Required:	No
	Notes:			The default NAT Loopback is that developed by Merlin and has been used in all fork
					firmware levels which have been released.   Merlin's implementation employs
					iptables marks in it's implementation.   This alternate method does not use
					marks and may be helpful if the user is employing custom marks.   Note also
					that in V17 the standard Merlin implementation has been changed to only use
					a single bit, to aid users who what to perform custom packet marking.
---------------------------------------------------------------------------------------------------------------
Ability to disable DNSSEC permissive mode

	Can be set in gui:	No
	Enable via NVRAM:	nvram set dnssec_check_unsigned=1
				nvram commit && reboot

	Routers Supported:	All
	Released:		Update-17
	Reboot Required:	No
	Notes:			By default, DNSSEC will also accept unsigned responses.  This option forces DNSSEC
					to only accept signed responses.  USE WITH CAUTION:  This can disable dns lookups
					if no DNSSEC enabled servers are available.
---------------------------------------------------------------------------------------------------------------
Ability to enable DFS channels for N66U EU routers

	Can be set in gui:	No
	Enable via NVRAM:	nvram set wl_dfs_enable=1
				nvram commit && reboot

	Routers Supported:	N66U/R/W
	Released:		Update-18
	Reboot Required:	Yes
	Notes:			The base 374.43 firmware only supports the lower channels on the 5GHz band in
					EU configured routers.
				This setting enables support for the DFS and upper 5GHz channels with full regulatory
					support.
---------------------------------------------------------------------------------------------------------------
Ability to set the Site Level Aggregation identifier (sla-id)

	Can be set in gui:	No
	Enable via NVRAM:	nvram set ipv6_slaid=[number]
				nvram commit && reboot

	Routers Supported:	All
	Released:		Update-19
	Reboot Required:	Yes
	Notes:			Sets which prefix out of the delegation to use. This is 2^sla-id. If you have a /48, 
					valid values would be 2^16 or 0-65535. 
					If you had a /56, it would be 2^8 or 0-255. A /60 is 0-15.
---------------------------------------------------------------------------------------------------------------
Control release of IPv6 Addresses on exit

	Can be set in gui:	Yes
	Enable via NVRAM:	nvram set ipv6_dhcp6c_release=[1 release,  0 no release]
				nvram commit && reboot

	Routers Supported:	All
	Released:		Update-19
	Reboot Required:	Yes
	Notes:			Release addresses on exit.  Not releases addresses allows some ISPs to continue to assign the 
					same IPv6 addresses.
---------------------------------------------------------------------------------------------------------------
Ability force a DHCPv6 request during IPv6 prefix delegation

	Can be set in gui:	Yes
	Enable via NVRAM:	nvram set ipv6_dhcp6c_force=1
				nvram commit && reboot

	Routers Supported:	All
	Released:		Update-19
	Reboot Required:	Yes
	Notes:			Some ISPs will not send an IPv6 prefix without an address REQUEST.  
					Sky UK is known to require this option.
---------------------------------------------------------------------------------------------------------------
Special IPv6 options

	Can be set in gui:	No
	Enable via NVRAM:	nvram set ipv6_isp_opt=xx
				nvram commit && reboot

	Routers Supported:	All
	Released:		Update-20
	Reboot Required:	Yes
	Notes:			ipv6_isp_opt is a mask with the following options
					ipv6_isp_opt=16 : Disable rapid-commit for dhcp6 server
					ipv6_isp_opt=8  : Disable rapid-commit for dhcp6c client
					ipv6_isp_opt=4  : Send generic ia-na=0 (default is calculated value based on MAC)
					ipv6_isp_opt=2  : Don't send prefix length, preferred lifetime hint (this may be invalid)
					ipv6_isp_opt=1  : Force default ipv6 route if not set by ISP

					The default value is ipv6_isp_opt=0. Add the values to select multiple options.
---------------------------------------------------------------------------------------------------------------
OpenVPN Client Reverse Strict DNS

	Can be set in gui:	No
	Enable via NVRAM:	nvram set vpn_reverse_strict=1
				nvram commit && reboot

	Routers Supported:	All
	Released:		Update-23
	Reboot Required:	No - alternatively can restart the VPN Client
	Notes:			The OpenVPN DNS strict option causes dnsmasq to access the DNS servers in order, first to last,
					with the DNS servers provided by the VPN added BEFORE the defined WAN servers.
				Setting this option causes the VPN DNS servers to be appended to the list of servers AFTER the WAN
					defined servers, so they will be accessed only if the WAN defined servers are unavailable.
					This may be useful if you are running a DNS server on your local LAN.
---------------------------------------------------------------------------------------------------------------
IPv6 Local Name Resolution

	Can be set in gui:	Yes
	Enable via NVRAM:	No
				Enable by adding the following lines to /jffs/configs/dnsmasq.conf.add

				dhcp-script=/usr/sbin/v6hosts.sh
				addn-hosts=/_etc/hosts.autov6

	Routers Supported:	All
	Released:		Update-23
	Reboot Required:	No - if manually configuring restart dnsmasq
	Notes:			Add script for IPv6 hosts auto update for native/stateless IPv6
					(adds local ipv6 name resolution to public address)
---------------------------------------------------------------------------------------------------------------
Move certs from NVRAM to JFFS

	Can be set in gui:	No
	Enable via NVRAM:	No
				This function is provided via command line using telnet/ssh

				To move the SSH (dropbear certs), enter
				sshd2jffs or
				sshd2nvram

				To move the OpenVPN certs, enter
				ovpn2jffs  [server1|server2|client1|client2] or
				ovpn2nvram [server1|server2|client1|client2]

				At the end of the command execution, you will be prompted to reboot the router

	Routers Supported:	All
	Released:		Update-24
	Reboot Required:	Yes
	Notes:			These commands can free NVRAM space by moving certificates/keys from NVRAM to JFFS (and back if required).
				They may be used if you are receiving a low NVRAM warning from the router gui.
				IMPORTANT:  If you wish to revert to a firmware prior to Update-24 and have moved the certs to JFFS,
					you MUST move them back to NVRAM prior to loading the earlier firmware.
---------------------------------------------------------------------------------------------------------------

Disabling the special options:

For options set with 'nvram set variable=1', setting 'nvram set variable=0' will disable
	(nvram commit and reboot if required)

For options set with 'nvram set variable=some_string', setting the with no data 'nvram set variable=', 
	will disable (nvram commit and reboot if required)

Alternatively you can erase the variable with 'nvram unset variable' (nvram commit and reboot if required)